POOL PHOTOVOLTAIC SYSTEM

光伏泳池循环泵
Shared Solar for Pool Heating & Circulation

Equip a new pool with a solar heat pump and circulation pump, or upgrade one unit in an existing pool while supplying retained equipment with solar/grid hybrid AC.

01

One solar system, two daily needs

Use daytime solar energy for both water temperature control and circulation.

02

Complete installation or selective upgrade

Choose both Eternal units or replace just the heat pump or circulation pump.

03

Retain equipment, add solar energy

The dedicated energy manager uses IBOX 220V AC hybrid output for existing AC equipment.

01 / SYSTEM TOPOLOGY

Choose the architecture
around your equipment.

The configurations differ by which equipment Eternal supplies and how retained equipment receives power.

One HS3000 shares solar energy

Both Eternal units include a solar hybrid drive. HS3000 distributes solar DC to both units; the grid connects to their AC inputs, and each integrated drive manages hybrid supply.

For pools installing both units. One-to-two means shared solar energy; the heat pump and circulation pump operate individually.

Direct DC connection requires a compatible solar hybrid drive, not merely an inverter label. Size the HS3000 arrangement for the combined electrical input and simultaneous operating duty; the full product range below does not imply every pair fits one HS3000. Match retained AC equipment to voltage, phase, starting current and IBOX output capacity.

DC to the new pump, 220V AC to the existing heat pump

Solar and grid connect to the dedicated pool energy manager. Its DC output serves the Eternal circulation pump with a solar hybrid drive. The integrated IBOX combines solar and grid energy into 220V AC for the existing heat pump and compatible AC equipment.

Retain the existing heat pump. The pump also retains the grid AC path shown in the diagram; existing AC equipment uses the manager’s 220V AC hybrid output.


HS solar management

Manages solar input and the DC supply path.

Integrated motor drive

Integrated with HS and IBOX in the dedicated manager; drive interfaces follow the selected equipment.

IBOX · 220V AC hybrid output

Combines solar and grid energy into 220V AC for existing AC equipment.

Direct DC connection requires a compatible solar hybrid drive, not merely an inverter label. Size the HS3000 arrangement for the combined electrical input and simultaneous operating duty; the full product range below does not imply every pair fits one HS3000. Match retained AC equipment to voltage, phase, starting current and IBOX output capacity.

DC to the new heat pump, 220V AC to the existing pump

Solar and grid connect to the dedicated pool energy manager. Its DC output serves the Eternal heat pump with a solar hybrid drive. The integrated IBOX supplies solar/grid hybrid 220V AC to the existing AC circulation pump.

Retain the existing AC circulation pump. The heat pump retains its grid AC path as shown; new and existing equipment connect to their respective outputs.


HS solar management

Manages solar input and the DC supply path.

Integrated motor drive

Integrated with HS and IBOX in the dedicated manager; drive interfaces follow the selected equipment.

IBOX · 220V AC hybrid output

Combines solar and grid energy into 220V AC for existing AC equipment.

Direct DC connection requires a compatible solar hybrid drive, not merely an inverter label. Size the HS3000 arrangement for the combined electrical input and simultaneous operating duty; the full product range below does not imply every pair fits one HS3000. Match retained AC equipment to voltage, phase, starting current and IBOX output capacity.

02 / PRODUCTS & SPECIFICATIONS

Select the heat pump
and circulation pump.

Product images accompany selectable text tables. Read heat-pump data by model and test condition, and pump data by source group and operating speed.

选择完整型号:▾

BYC-007SD1

Heating · Air 26 °C

Humidity 80% · Water in 26 °C / out 28 °C

Parameter Unit Value
Heating capacity kW 7.6–1.7
Power input kW 1.12–0.11
COP W/W 15.8–6.8

Heating · Air 15 °C

Humidity 70% · Water in 26 °C / out 28 °C

Parameter Unit Value
Heating capacity kW 6.1–1.4
Power input kW 1.24–0.18
COP W/W 7.6–4.9

Cooling · Air 35 °C

Water in 29 °C / out 27 °C

Parameter Unit Value
Cooling capacity kW 4.2–1.0
Power input kW 1.11–0.15
EER W/W 6.6–3.8

Electrical, installation & operation

Dimensions follow source order; AC supply as listed

Parameter Unit Value
AC supply V / Ph / Hz 220–240 / 1 / 50
Max. power input (source) kW 1.55
Max. current (source) A 7.3
Water flow m³/h 2.5
Noise at 1 m dB(A) 39–49
Noise at 10 m dB(A) 20–29
Net weight kg 42
Gross weight kg 53
Unit dimensions mm 864 × 349 × 592
Package dimensions mm 930 × 400 × 640

Shared series specifications

Refrigerant

R32

Operating temperature

−15~43 °C

Heat exchanger

Titanium

Casing

ABS

Air discharge

Horizontal

Protection

IPX4

Automatic defrost

4-way valve

Control

Built-in Wi-Fi / EEV

BYC-010SD1

Heating · Air 26 °C

Humidity 80% · Water in 26 °C / out 28 °C

Parameter Unit Value
Heating capacity kW 9.5–2.3
Power input kW 1.40–0.15
COP W/W 15.8–6.8

Heating · Air 15 °C

Humidity 70% · Water in 26 °C / out 28 °C

Parameter Unit Value
Heating capacity kW 7.6–1.9
Power input kW 1.55–0.25
COP W/W 7.6–4.9

Cooling · Air 35 °C

Water in 29 °C / out 27 °C

Parameter Unit Value
Cooling capacity kW 5.3–1.3
Power input kW 1.40–0.19
EER W/W 6.7–3.8

Electrical, installation & operation

Dimensions follow source order; AC supply as listed

Parameter Unit Value
AC supply V / Ph / Hz 220–240 / 1 / 50
Max. power input (source) kW 1.78
Max. current (source) A 8.3
Water flow m³/h 3.5
Noise at 1 m dB(A) 40–52
Noise at 10 m dB(A) 20–32
Net weight kg 43
Gross weight kg 54
Unit dimensions mm 864 × 349 × 592
Package dimensions mm 930 × 400 × 640

Shared series specifications

Refrigerant

R32

Operating temperature

−15 ~ 43 °C

Heat exchanger

Titanium

Casing

ABS

Air discharge

Horizontal

Protection

IPX4

Automatic defrost

4-way valve

Control

Built-in Wi-Fi / EEV

BYC-013SD1

Heating · Air 26 °C

Humidity 80% · Water in 26 °C / out 28 °C

Parameter Unit Value
Heating capacity kW 13–3.0
Power input kW 1.91–0.19
COP W/W 16–6.8

Heating · Air 15 °C

Humidity 70% · Water in 26 °C / out 28 °C

Parameter Unit Value
Heating capacity kW 9.8–2.3
Power input kW 1.96–0.30
COP W/W 7.6–5

Cooling · Air 35 °C

Water in 29 °C / out 27 °C

Parameter Unit Value
Cooling capacity kW 7.2–1.7
Power input kW 1.89–0.25
EER W/W 6.7–3.8

Electrical, installation & operation

Dimensions follow source order; AC supply as listed

Parameter Unit Value
AC supply V / Ph / Hz 220–240 / 1 / 50
Max. power input (source) kW 2.2
Max. current (source) A 10.2
Water flow m³/h 4.5
Noise at 1 m dB(A) 42–53
Noise at 10 m dB(A) 22–33
Net weight kg 53
Gross weight kg 64
Unit dimensions mm 925 × 364 × 642
Package dimensions mm 990 × 435 × 760

Shared series specifications

Refrigerant

R32

Operating temperature

−15 ~ 43 °C

Heat exchanger

Titanium

Casing

ABS

Air discharge

Horizontal

Protection

IPX4

Automatic defrost

4-way valve

Control

Built-in Wi-Fi / EEV

BYC-017SD1

Heating · Air 26 °C

Humidity 80% · Water in 26 °C / out 28 °C

Parameter Unit Value
Heating capacity kW 17–3.8
Power input kW 2.5–0.24
COP W/W 15.8–6.8

Heating · Air 15 °C

Humidity 70% · Water in 26 °C / out 28 °C

Parameter Unit Value
Heating capacity kW 13.5–3
Power input kW 2.76–0.39
COP W/W 7.6–4.9

Cooling · Air 35 °C

Water in 29 °C / out 27 °C

Parameter Unit Value
Cooling capacity kW 9.4–2.1
Power input kW 2.47–0.31
EER W/W 6.7–3.8

Electrical, installation & operation

Dimensions follow source order; AC supply as listed

Parameter Unit Value
AC supply V / Ph / Hz 220–240 / 1 / 50
Max. power input (source) kW 2.6
Max. current (source) A 12
Water flow m³/h 5.5
Noise at 1 m dB(A) 43–55
Noise at 10 m dB(A) 23–35
Net weight kg 54
Gross weight kg 65
Unit dimensions mm 925 × 364 × 642
Package dimensions mm 990 × 435 × 760

Shared series specifications

Refrigerant

R32

Operating temperature

−15 ~ 43 °C

Heat exchanger

Titanium

Casing

ABS

Air discharge

Horizontal

Protection

IPX4

Automatic defrost

4-way valve

Control

Built-in Wi-Fi / EEV

BYC-021SD1

Heating · Air 26 °C

Humidity 80% · Water in 26 °C / out 28 °C

Parameter Unit Value
Heating capacity kW 21–4.8
Power input kW 3.09–0.30
COP W/W 15.8–6.8

Heating · Air 15 °C

Humidity 70% · Water in 26 °C / out 28 °C

Parameter Unit Value
Heating capacity kW 16.5–3.8
Power input kW 3.37–0.5
COP W/W 7.6–4.9

Cooling · Air 35 °C

Water in 29 °C / out 27 °C

Parameter Unit Value
Cooling capacity kW 11.6–2.7
Power input kW 3.05–0.4
EER W/W 6.7–3.8

Electrical, installation & operation

Dimensions follow source order; AC supply as listed

Parameter Unit Value
AC supply V / Ph / Hz 220–240 / 1 / 50
Max. power input (source) kW 3.2
Max. current (source) A 14.7
Water flow m³/h 6.5
Noise at 1 m dB(A) 45–56
Noise at 10 m dB(A) 25–36
Net weight kg 58
Gross weight kg 69
Unit dimensions mm 925 × 364 × 642
Package dimensions mm 990 × 435 × 760

Shared series specifications

Refrigerant

R32

Operating temperature

−15 ~ 43 °C

Heat exchanger

Titanium

Casing

ABS

Air discharge

Horizontal

Protection

IPX4

Automatic defrost

4-way valve

Control

Built-in Wi-Fi / EEV

BYC-030SD1

Heating · Air 26 °C

Humidity 80% · Water in 26 °C / out 28 °C

Parameter Unit Value
Heating capacity kW 28–6.8
Power input kW 4.12–0.43
COP W/W 15.8–6.8

Heating · Air 15 °C

Humidity 70% · Water in 26 °C / out 28 °C

Parameter Unit Value
Heating capacity kW 23–5.5
Power input kW 4.7–0.72
COP W/W 7.6–4.9

Cooling · Air 35 °C

Water in 29 °C / out 27 °C

Parameter Unit Value
Cooling capacity kW 14.9–3.8
Power input kW 3.92–0.57
EER W/W 6.7–3.8

Electrical, installation & operation

Dimensions follow source order; AC supply as listed

Parameter Unit Value
AC supply V / Ph / Hz 220–240 / 1 / 50
Max. power input (source) kW 4.55
Max. current (source) A 20.4
Water flow m³/h 9
Noise at 1 m dB(A) 47–58
Noise at 10 m dB(A) 27–38
Net weight kg 88
Gross weight kg 99
Unit dimensions mm 1084 × 399 × 737
Package dimensions mm 1146 × 460 × 862

Shared series specifications

Refrigerant

R32

Operating temperature

−15 ~ 43 °C

Heat exchanger

Titanium

Casing

ABS

Air discharge

Horizontal

Protection

IPX4

Automatic defrost

4-way valve

Control

Built-in Wi-Fi / EEV

BYC-035SD1

Heating · Air 26 °C

Humidity 80% · Water in 26 °C / out 28 °C

Parameter Unit Value
Heating capacity kW 35–8.8
Power input kW 5.15–0.56
COP W/W 15.8–6.8

Heating · Air 15 °C

Humidity 70% · Water in 26 °C / out 28 °C

Parameter Unit Value
Heating capacity kW 25.5–6.4
Power input kW 5.2–0.84
COP W/W 7.6–4.9

Cooling · Air 35 °C

Water in 29 °C / out 27 °C

Parameter Unit Value
Cooling capacity kW 19.3–4.9
Power input kW 5.08–0.73
EER W/W 6.7–3.8

Electrical, installation & operation

Dimensions follow source order; AC supply as listed

Parameter Unit Value
AC supply V / Ph / Hz 220–240 / 1 / 50
Max. power input (source) kW 4.76
Max. current (source) A 30
Water flow m³/h 12
Noise at 1 m dB(A) 49–59
Noise at 10 m dB(A) 29–39
Net weight kg 98
Gross weight kg 110
Unit dimensions mm 1084 × 399 × 737
Package dimensions mm 1146 × 460 × 862

Shared series specifications

Refrigerant

R32

Operating temperature

−15 ~ 43 °C

Heat exchanger

Titanium

Casing

ABS

Air discharge

Horizontal

Protection

IPX4

Automatic defrost

4-way valve

Control

Built-in Wi-Fi / EEV

BYC-030SD3

Heating · Air 26 °C

Humidity 80% · Water in 26 °C / out 28 °C

Parameter Unit Value
Heating capacity kW 28–6.8
Power input kW 3.97–0.43
COP W/W 15.8–6.8

Heating · Air 15 °C

Humidity 70% · Water in 26 °C / out 28 °C

Parameter Unit Value
Heating capacity kW 23–5.5
Power input kW 4.7–0.72
COP W/W 7.6–4.9

Cooling · Air 35 °C

Water in 29 °C / out 27 °C

Parameter Unit Value
Cooling capacity kW 14.9–3.8
Power input kW 3.92–0.57
EER W/W 6.7–3.8

Electrical, installation & operation

Dimensions follow source order; AC supply as listed

Parameter Unit Value
AC supply V / Ph / Hz 380–415 / 3 / 50
Max. power input (source) kW 6.43
Max. current (source) A 7.9
Water flow m³/h 9
Noise at 1 m dB(A) 47–58
Noise at 10 m dB(A) 27–38
Net weight kg 88
Gross weight kg 99
Unit dimensions mm 1084 × 399 × 737
Package dimensions mm 1146 × 460 × 862

Shared series specifications

Refrigerant

R32

Operating temperature

−15 ~ 43 °C

Heat exchanger

Titanium

Casing

ABS

Air discharge

Horizontal

Protection

IPX4

Automatic defrost

4-way valve

Control

Built-in Wi-Fi / EEV

BYC-035SD3

Heating · Air 26 °C

Humidity 80% · Water in 26 °C / out 28 °C

Parameter Unit Value
Heating capacity kW 35–8.8
Power input kW 5.15–0.56
COP W/W 15.8–6.8

Heating · Air 15 °C

Humidity 70% · Water in 26 °C / out 28 °C

Parameter Unit Value
Heating capacity kW 25.5–6.4
Power input kW 5.4–0.84
COP W/W 7.6–4.9

Cooling · Air 35 °C

Water in 29 °C / out 27 °C

Parameter Unit Value
Cooling capacity kW 19.3–4.9
Power input kW 5.08–0.73
EER W/W 6.7–3.8

Electrical, installation & operation

Dimensions follow source order; AC supply as listed

Parameter Unit Value
AC supply V / Ph / Hz 380–415 / 3 / 50
Max. power input (source) kW 6.93
Max. current (source) A 11.3
Water flow m³/h 12
Noise at 1 m dB(A) 49–59
Noise at 10 m dB(A) 29–39
Net weight kg 98
Gross weight kg 110
Unit dimensions mm 1084 × 399 × 737
Package dimensions mm 1146 × 460 × 862

Shared series specifications

Refrigerant

R32

Operating temperature

−15 ~ 43 °C

Heat exchanger

Titanium

Casing

ABS

Air discharge

Horizontal

Protection

IPX4

Automatic defrost

4-way valve

Control

Built-in Wi-Fi / EEV

Ranges retain the brochure’s descending order. Some condition-specific input values exceed the source “maximum power input” row; both are shown separately and require verification before system sizing. Heating capacity is thermal output, not electrical input.

Permanent-magnet inverter circulation pump

For daily pool circulation, with permanent-magnet variable-speed operation, soft start and intelligent control. Select operating settings for the required flow, head and speed.

MPPT + ACSoft startWi-Fi option
选择完整型号:▾

VFP-150 · source group A

Each row matches a speed / operating point within the source group. Swipe the table horizontally on mobile.
Power kW HP (source) Max. head m Max. flow m³/h Speed r/min
0.4 0.5 6 14 1600
0.5 0.5 9 17 1900
0.7 0.5 11 20 2200
0.9 0.75 14 23 2500
1 1.2 18 29 2800
1.1 1.5 18 28 2800
Shared source specifications
Voltage
220 V / 380 V
Frequency
50 Hz / 60 Hz
Port (source)
63 mm / 2″
Control
Soft start · Optional Wi-Fi

VFP-150 · source group B

Each row matches a speed / operating point within the source group. Swipe the table horizontally on mobile.
Power kW HP (source) Max. head m Max. flow m³/h Speed r/min
0.5 0.6 7 17 1600
0.6 0.7 9 20 1900
0.8 0.9 12 23 2200
1 1.2 15 26 2500
1.3 1.5 18 28 2800
1.5 2 19 30 2900
Shared source specifications
Voltage
220 V / 380 V
Frequency
50 Hz / 60 Hz
Port (source)
63 mm / 2″
Control
Soft start · Optional Wi-Fi

VFP-300

Each row matches a speed / operating point within the source group. Swipe the table horizontally on mobile.
Power kW HP (source) Max. head m Max. flow m³/h Speed r/min
0.4 0.5 5 19 1600
0.6 0.75 7 21 1900
0.9 1.2 10 25 2200
Shared source specifications
Voltage
220 V / 380 V
Frequency
50 Hz / 60 Hz
Port (source)
63 mm / 2″
Control
Soft start · Optional Wi-Fi

VFP-350

Each row matches a speed / operating point within the source group. Swipe the table horizontally on mobile.
Power kW HP (source) Max. head m Max. flow m³/h Speed r/min
1.3 1.8 13 29 2500
1.8 2.5 17 32 2800
2.2 3 21 35 2900
Shared source specifications
Voltage
220 V / 380 V
Frequency
50 Hz / 60 Hz
Port (source)
63 mm / 2″
Control
Soft start · Optional Wi-Fi

The brochure labels both first groups VFP-150; A/B distinguishes source groups pending model confirmation. HP values are retained as supplied. Voltage is a shared source column; confirm the ordered supply variant. Maximum flow and head do not represent the same duty point.


▼ Compare all 9 models

ModelAC supply V/Ph/Hz26°C heating kWMax. input kW (source)Water flow m³/h
BYC-007SD1220–240 / 1 / 507.6–1.71.552.5
BYC-010SD1220–240 / 1 / 509.5–2.31.783.5
BYC-013SD1220–240 / 1 / 5013–3.02.24.5
BYC-017SD1220–240 / 1 / 5017–3.82.65.5
BYC-021SD1220–240 / 1 / 5021–4.83.26.5
BYC-030SD1220–240 / 1 / 5028–6.84.559
BYC-035SD1220–240 / 1 / 5035–8.84.7612
BYC-030SD3380–415 / 3 / 5028–6.86.439
BYC-035SD3380–415 / 3 / 5035–8.86.9312

03 / DOWNLOAD CENTER

样本与选型资料,
打开页面就能查看。

请下载全系列选型手册,查看完整型号、性能参数、安装尺寸与曲线。

全系列手册保留各型号原始电压、功率和安装资料