SOLAR MICROGRID AIR CONDITIONING

Solar Air Conditioner
One network. More rooms.

Share solar energy across multiple air conditioners and put sunlight to work during the day. Grid power covers the shortfall; storage is optional. Without grid power, compatible units can follow available solar energy when operating conditions are met.

Shared solar energy Multiple daytime spaces Optional storage

01 / Microgrid

Multi-unit microgrid

One solar energy system supplies multiple air conditioners and distributes available energy by room demand.

02 / Optional Storage

Optional energy storage

Store surplus daytime solar for later cooling. Daytime-focused projects can start without a battery.

03 / Solar Only

Solar-only operation

Without grid power or storage, cooling can adjust to available solar above the minimum operating threshold.

04 / AC/DC Coupling

AC/DC coupled supply

Use available solar first, with grid power supplying the remaining demand as sunlight changes.

Designed around multiple rooms with daytime cooling demand.

Schools

Classrooms, training spaces and offices

Hospitals

Outpatient, waiting and office areas

Commercial & industrial

Offices, shops and workplace facilities


01 / SYSTEM TOPOLOGY

From daytime cooling
to connected home loads.

Choose the configuration by operating hours and energy needs. Multiple independent air conditioners share a solar energy system; this is not a multi-split refrigerant circuit.

Use daytime solar across your rooms

PV supplies multiple independent air conditioners through an energy manager. Each air conditioner retains grid support. Suits daytime cooling in schools, hospital everyday spaces and business facilities.

The original diagram shows HS3000 with two air conditioners. Actual unit count depends on manager capacity, unit power and simultaneous demand.

Keep surplus solar for later cooling

Add a battery to the shared energy network to store surplus solar and supplement later cooling. Grid support remains available.

Storage runtime depends on usable capacity, actual cooling load and controls; it is not a fixed number of hours.

Use solar for more compatible home loads

Air conditioning uses the solar and grid supply paths. IBOX extends the energy system to compatible household loads, with storage participating as configured.

Appliances shown represent possible load types. Confirm compatibility, output type and supported power against IBOX specifications and project configuration.

02 / AIR CONDITIONER SERIES

Choose the format.
Check the specifications.

The current page shows split and mobile systems. A portable section follows the same image-and-spec format and will be added later.

01

Split systems

SPLIT SYSTEM · AC/DC E-HYBRID

Split-system microgrid air conditioning

Independent indoor and outdoor units serve individual rooms while sharing solar energy through an energy manager. The current range is shown in 12,000 and 18,000 BTU classes.
  • Cooling class
  • 12,000 / 18,000 BTU
  • Refrigerant
  • R32
  • Operation
  • Cooling / heating

Split-system specifications

Parameter Unit 12,000 BTU 18,000 BTU
Capacity & performance
Nominal cooling capacity¹ BTU/h 12,000 18,000
Cooling capacity range¹ BTU/h 2,047–12,215 4,260–20,000
Nominal heating capacity¹ BTU/h 12,500 18,400
Heating capacity range¹ BTU/h 2,047–12,727 4,260–20,000
Cooling input power W 980 (300–1,380) 1,600 (330–2,340)
Heating input power W 1,000 (300–1,350) 1,479 (340–2,520)
Cooling running current A 5.2 7.5 (1.7–12.0)
Heating running current A 5.3 6.5 (1.7–13.0)
Dehumidification kg/h 1.0 1.8
Electrical & refrigeration
Power supply V / Ph / Hz 230 V · 1Ph · 50/60 Hz + DC 230 V · 1Ph · 50/60 Hz + DC
Maximum input power W 1,600 2,500
Maximum input current A 9 12.5
Refrigerant — R32 R32
Refrigerant charge g 500 910
Design pressure, high side MPa 4.3 4.3
Design pressure, low side MPa 2.5 2.5
Airflow, noise & weight
Airflow m³/h 600 740
Noise reference value² dB(A) 42 / 51 43 / 55
Indoor net weight kg 8.5 11
Outdoor net weight kg 25 29.5
02

Mobile air conditioners

MOBILE AIR CONDITIONER · INVERTER

YPT-12C/H (A+) mobile air conditioner

A single-duct inverter mobile air conditioner with cooling, heating and dehumidification.
  • Cooling capacity
  • 12,000 BTU/h · 3,500 W
  • Heating capacity
  • 10,000 BTU/h · 2,930 W
  • Refrigerant
  • R290

Mobile air conditioner specifications

Parameter Unit YPT-12C/H (A+)
Product type — Single-duct inverter
Cooling capacity BTU/h / W 12,000 / 3,500
Heating capacity BTU/h / W 10,000 / 2,930
Power supply V / Hz 230 V / 50 Hz
Rated cooling input W 1,130
Rated cooling current A 5.0
Rated heating input W 945
Rated heating current A 4.2
EER W/W 3.10
COP W/W 3.10
Refrigerant — R290
Airflow m³/h 440
Body dimensions³ (source order) mm 450 × 363 × 704
Package dimensions³ (source order) mm 478 × 406 × 882
Net / gross weight (cooling & heating) kg 24.5 / 29
Application volume m³ 105
Loading quantity / 40′ HQ 台 / units 415
Loading quantity / 40′ GP 台 / units 280
Loading quantity / 20′ 台 / units 136
Moisture removal L/h 1.2

Dimensions are given as W × H × D in factory order; confirm axis order against the installation drawing.

03

Carry-portable air conditioners

Carry-portable air conditioners

Carry-portable air conditioners

Reserved for carry-portable photography, weight, power supply and cooling data. No unconfirmed models or performance values are listed.

Specification template

Parameter Unit Model pending
Model — Pending
Nominal cooling capacity BTU/h / W Pending
Heating capacity, if applicable BTU/h / W Pending
Supply & solar interface V / Ph / Hz; DC Pending
Rated input power / current W / A Pending
Refrigerant & charge — / g Pending
Airflow / noise m³/h / dB(A) Pending
Dimensions (W × H × D) mm Pending
Net / gross weight kg Pending
Controls & integration notes — Pending

Keep the series name, product photo, specification table and matched downloads together. Confirm microgrid compatibility for each new model.

03 / DOWNLOAD CENTER

Selection resources.
All in one place.

Download the complete brochure and model data for project discussions, equipment checks and selection records.

Full performance curves, installation drawings and solar-interface specifications are not included — contact us if you need them.