Configure solar ventilation for livestock buildings, greenhouses and agricultural facilities. Select an energy architecture, then match direct-drive fans by housing material, airflow and static pressure.
3 energy architectures3 housing categories8 direct-drive series
01 / SYSTEM TOPOLOGY
One fan network. Three energy configurations.
Choose solar-grid coupling, DC-side storage or PCS backup according to the site’s supply and ventilation continuity requirements.
Solar for everyday ventilation
PV connects to the Solar/DC bus through the energy controller. An independent AC bus supplies all fan controllers from the grid.
No storage. During an outage, solar-following operation depends on sunlight, PV capacity, and compatible controls.
Backup power for essential ventilation
Grid and diesel generator feed the PCS, which supplies the downstream AC bus. Solar retains a separate solar/DC path.
The grid does not bypass the PCS. Confirm the switchover time and ventilation backup duration against the PCS specifications and system capacity.
02 / DIRECT-DRIVE FAN SELECTION
Choose the housing. Match the fan to your site.
Each series includes the original product image, specification table and downloadable selection sheet. Categories follow housing material; blade material is listed separately.
Always read airflow together with its static pressure: 0 Pa, 100 Pa, and 200 Pa are different operating conditions. Values without a stated pressure are for reference only and are not directly comparable.
01
FRP & enhanced FRP
Standard, enhanced, DN-FRP and MF50 series.
Enhanced FRP housing
Enhanced FRP fans
Larger sizes for higher airflow requirements.
Size
36 / 51 / 54–55 / 57″
Power
0.75–1.8 kW
Supply
380 V · 50 Hz
Size
Frame (mm)
Opening (mm)
Direct drive
Airflow (m³/h)
57"
1720 × 1720
1680 × 1680
3-blade PAG · 1.8 kW
69,000
54/55"
1630 × 1630
1580 × 1580
3-blade PAG · 1.5 kW
60,500
51"
1526 × 1526
1460 × 1460
3-blade PAG · 1.5 kW
52,000
36"
1170 × 1170
1090 × 1090
3-blade PAG · 0.75 kW
25,500
Listed as “New FRP fans” in the source manual. Static pressure is not specified.
FRP / nylon (source classification)
MF50 cone fans
EC and AC variants with airflow at defined pressure points.
Size
50″ · 1.5 kW
Blades
5 × PP
Protection
IP66
Model
Motor · A · RPM
Supply
0 Pa (m³/h)
50 Pa (m³/h)
100 Pa (m³/h)
ZMD50-2-1.5ECS-125
EC · 2.8 A · 715
380–460 V / 50–60 Hz
52,200
46,500
34,400
ZMD50-2-1.5YSP8-125
AC · 4.6 A · 695
380 V / 50 Hz
51,800
45,400
37,700
Dimensions: 1380 × 1380 mm (housing), 1200 mm (cone), and 1625 mm overall height. Housing classification follows the overview; confirm component materials and dimension directions against the drawings.
FRP housing
Standard FRP fans
Four sizes for different ventilation requirements.
Size
24 / 36 / 42 / 50″
Power
0.55–1.5 kW
Supply
380 V · 50 Hz
Size
Frame (mm)
Opening (mm)
Direct drive
Airflow (m³/h)
50"
1460 × 1460
1400 × 1400
3-blade cast aluminum/ Cast Al · 1.5 kW
45,300
42"
1260 × 1260
1200 × 1200
3-blade cast aluminum / Cast Al · 1.1 kW
32,000
36"
1060 × 1060
1000 × 1000
3-blade PAG · 0.75 kW
24,000
24"
850 × 850
800 × 800
6-blade PAG · 0.55 kW
12,600
Only explicitly direct-drive configurations are included. Static pressure is not specified for these airflow values.
FRP housing
DN-FRP series
Check airflow, depth and supply by the documented model.
Listed power
0.55–1.1 kW
Voltage
220 / 380 V
Noise
60–70 dB
Model
Dimensions (mm)
Power (kW)
Airflow (m³/h)
Noise (dB)
DN-FRP-1460
1460 × 1460 × 590
1.1
36,000
60–70
DN-FRP-1060
1060 × 1060 × 560
0.55
19,000
60–70
850 and 1260 are series members without individual data in the source table. Pressure is unspecified, confirm voltage by model. The source image includes two housing types, this series refers only to FRP.
02
Galvanized steel housings
JFDZ push-pull and 138 cone models, with mixed materials identified.
Galvanized housing + FRP collector
138 cone fans
A metal housing paired with an FRP air collector.
Dimensions
1380 × 1380 × 1200 mm
Power
1.5 kW
Blades
5 × PP / Composite PP
Variant
Power (kW)
0 Pa (m³/h)
50 Pa (m³/h)
AC
1.5
51,800
45,400
EC
1.5
52,200
46,500
Three-phase 380 V, 50/60 Hz. The manual specifies “275g” galvanized steel; confirm the coating specification separately. Shares source page 9 with 36 EC.
Galvanized steel housing
JFDZ push-pull fans
Square housing with multiple direct-drive motor options.
Power
1.1 kW
Frame
1380 × 1380 mm
Blades
Stainless steel · PAG
Model
Diameter (mm)
Speed (RPM)
Motor
Airflow (m³/h)
JFDZ-1250
1270
420
EC External rotor
42,000
JFDZ-1250
1270
480
EC Internal rotor
45,000
JFDZ-1310 (EC)
1310
710
EC
47,000
JFDZ-1310 (AC)
1310
710
AC
46,000
Depth is 450 / 500 / 520 mm depending on configuration. Confirm blade material by model. Static pressure and supply voltage are not specified.
03
Composite PP housings
EC high-pressure direct-drive series; select at the operating pressure.
Composite PP housing
36 EC high-pressure direct-drive fans
Compare performance at 100 Pa and 200 Pa.
Dimensions
1130 × 1130 × 440 mm
Supply
3~ 380 V · 50 Hz
Blades
7 × PP / Composite PP
Variant
Power (kW)
100 Pa (m³/h)
200 Pa (m³/h)
EC
3.0
34,400
30,100
EC
3.5
34,800
32,000
Airflow is stated at 100 Pa / 200 Pa and must not be compared directly with other series at 0 Pa. Shares source page 9 with the 138 model.
Composite PP housing
Plusfan 36 EC high-pressure fans
Representative airflow data from 0 to 400 Pa.
Dimensions
1130 × 1130 × 440 mm
Supply
3~ 380 V · 50 Hz
Blades
7 × PP · IP66
Model
Power · Current
0 Pa (m³/h)
100 Pa (m³/h)
200 Pa (m³/h)
400 Pa (m³/h)
ZP36-2-2.3-5ECS-400
3.5 kW · 6.6 A
36,800
34,800
32,000
23,400
ZP36-2-3ECS-350
3.0 kW · 6.0 A
36,600
34,400
30,100
11,300
Airflow is listed at the representative 1150 RPM condition. Check the full performance curve for project selection.
03 / DOWNLOAD CENTER
Selection resources. All in one place.
Download the complete brochure and model data for project discussions, equipment checks and selection records.
Full performance curves, installation drawings and solar-interface specifications are not included — contact us if you need them.