AGRICULTURE & LIVESTOCK

Solar Exhaust Fan
From energy to airflow.

Configure solar ventilation for livestock buildings, greenhouses and agricultural facilities. Select an energy architecture, then match direct-drive fans by housing material, airflow and static pressure.

3 energy architectures 3 housing categories 8 direct-drive series

01 / SYSTEM TOPOLOGY

One fan network.
Three energy configurations.

Choose solar-grid coupling, DC-side storage or PCS backup according to the site’s supply and ventilation continuity requirements.

Solar for everyday ventilation

PV connects to the Solar/DC bus through the energy controller. An independent AC bus supplies all fan controllers from the grid.

No storage. During an outage, solar-following operation depends on sunlight, PV capacity, and compatible controls.

Backup power for essential ventilation

Grid and diesel generator feed the PCS, which supplies the downstream AC bus. Solar retains a separate solar/DC path.

The grid does not bypass the PCS. Confirm the switchover time and ventilation backup duration against the PCS specifications and system capacity.

02 / DIRECT-DRIVE FAN SELECTION

Choose the housing.
Match the fan to your site.

Each series includes the original product image, specification table and downloadable selection sheet. Categories follow housing material; blade material is listed separately.

Always read airflow together with its static pressure: 0 Pa, 100 Pa, and 200 Pa are different operating conditions. Values without a stated pressure are for reference only and are not directly comparable.

01

FRP & enhanced FRP

Standard, enhanced, DN-FRP and MF50 series.

Enhanced FRP housing

Enhanced FRP fans

Larger sizes for higher airflow requirements.
  • Size
  • 36 / 51 / 54–55 / 57″
  • Power
  • 0.75–1.8 kW
  • Supply
  • 380 V · 50 Hz
Size Frame (mm) Opening (mm) Direct drive Airflow (m³/h)
57" 1720 × 1720 1680 × 1680 3-blade PAG · 1.8 kW 69,000
54/55" 1630 × 1630 1580 × 1580 3-blade PAG · 1.5 kW 60,500
51" 1526 × 1526 1460 × 1460 3-blade PAG · 1.5 kW 52,000
36" 1170 × 1170 1090 × 1090 3-blade PAG · 0.75 kW 25,500

Listed as “New FRP fans” in the source manual. Static pressure is not specified.

FRP / nylon (source classification)

MF50 cone fans

EC and AC variants with airflow at defined pressure points.
  • Size
  • 50″ · 1.5 kW
  • Blades
  • 5 × PP
  • Protection
  • IP66
Model Motor · A · RPM Supply 0 Pa (m³/h) 50 Pa (m³/h) 100 Pa (m³/h)
ZMD50-2-1.5ECS-125 EC · 2.8 A · 715 380–460 V / 50–60 Hz 52,200 46,500 34,400
ZMD50-2-1.5YSP8-125 AC · 4.6 A · 695 380 V / 50 Hz 51,800 45,400 37,700

Dimensions: 1380 × 1380 mm (housing), 1200 mm (cone), and 1625 mm overall height. Housing classification follows the overview; confirm component materials and dimension directions against the drawings.

FRP housing

Standard FRP fans

Four sizes for different ventilation requirements.
  • Size
  • 24 / 36 / 42 / 50″
  • Power
  • 0.55–1.5 kW
  • Supply
  • 380 V · 50 Hz
Size Frame (mm) Opening (mm) Direct drive Airflow (m³/h)
50" 1460 × 1460 1400 × 1400 3-blade cast aluminum/ Cast Al · 1.5 kW 45,300
42" 1260 × 1260 1200 × 1200 3-blade cast aluminum / Cast Al · 1.1 kW 32,000
36" 1060 × 1060 1000 × 1000 3-blade PAG · 0.75 kW 24,000
24" 850 × 850 800 × 800 6-blade PAG · 0.55 kW 12,600

Only explicitly direct-drive configurations are included. Static pressure is not specified for these airflow values.

FRP housing

DN-FRP series

Check airflow, depth and supply by the documented model.
  • Listed power
  • 0.55–1.1 kW
  • Voltage
  • 220 / 380 V
  • Noise
  • 60–70 dB
Model Dimensions (mm) Power (kW) Airflow (m³/h) Noise (dB)
DN-FRP-1460 1460 × 1460 × 590 1.1 36,000 60–70
DN-FRP-1060 1060 × 1060 × 560 0.55 19,000 60–70

850 and 1260 are series members without individual data in the source table. Pressure is unspecified, confirm voltage by model.
The source image includes two housing types, this series refers only to FRP.

02

Galvanized steel housings

JFDZ push-pull and 138 cone models, with mixed materials identified.

Galvanized housing + FRP collector

138 cone fans

A metal housing paired with an FRP air collector.
  • Dimensions
  • 1380 × 1380 × 1200 mm
  • Power
  • 1.5 kW
  • Blades
  • 5 × PP / Composite PP
Variant Power (kW) 0 Pa (m³/h) 50 Pa (m³/h)
AC 1.5 51,800 45,400
EC 1.5 52,200 46,500

Three-phase 380 V, 50/60 Hz. The manual specifies “275g” galvanized steel; confirm the coating specification separately. Shares source page 9 with 36 EC.

Galvanized steel housing

JFDZ push-pull fans

Square housing with multiple direct-drive motor options.
  • Power
  • 1.1 kW
  • Frame
  • 1380 × 1380 mm
  • Blades
  • Stainless steel · PAG
Model Diameter (mm) Speed (RPM) Motor Airflow (m³/h)
JFDZ-1250 1270 420 EC External rotor 42,000
JFDZ-1250 1270 480 EC Internal rotor 45,000
JFDZ-1310 (EC) 1310 710 EC 47,000
JFDZ-1310 (AC) 1310 710 AC 46,000

Depth is 450 / 500 / 520 mm depending on configuration. Confirm blade material by model. Static pressure and supply voltage are not specified.

03

Composite PP housings

EC high-pressure direct-drive series; select at the operating pressure.

Composite PP housing

36 EC high-pressure direct-drive fans

Compare performance at 100 Pa and 200 Pa.
  • Dimensions
  • 1130 × 1130 × 440 mm
  • Supply
  • 3~ 380 V · 50 Hz
  • Blades
  • 7 × PP / Composite PP
Variant Power (kW) 100 Pa (m³/h) 200 Pa (m³/h)
EC 3.0 34,400 30,100
EC 3.5 34,800 32,000

Airflow is stated at 100 Pa / 200 Pa and must not be compared directly with other series at 0 Pa. Shares source page 9 with the 138 model.

Composite PP housing

Plusfan 36 EC high-pressure fans

Representative airflow data from 0 to 400 Pa.
  • Dimensions
  • 1130 × 1130 × 440 mm
  • Supply
  • 3~ 380 V · 50 Hz
  • Blades
  • 7 × PP · IP66
Model Power · Current 0 Pa (m³/h) 100 Pa (m³/h) 200 Pa (m³/h) 400 Pa (m³/h)
ZP36-2-2.3-5ECS-400 3.5 kW · 6.6 A 36,800 34,800 32,000 23,400
ZP36-2-3ECS-350 3.0 kW · 6.0 A 36,600 34,400 30,100 11,300

Airflow is listed at the representative 1150 RPM condition. Check the full performance curve for project selection.

03 / DOWNLOAD CENTER

Selection resources.
All in one place.

Download the complete brochure and model data for project discussions, equipment checks and selection records.

Full performance curves, installation drawings and solar-interface specifications are not included — contact us if you need them.