Solar Industrial Circulation Pump
Solar retrofit control cabinet

Keep the existing pump and add solar energy. Combine TS6000 energy managers with one matched drive in a retrofit control cabinet, sized for the existing motor and circulation system.

Drive reference range 5.5–45 kW 380V · 3-phase Sized for the existing pump

01

Keep the pump. Upgrade the supply.

Retrofit around the existing pump, motor and pipework. The cabinet integrates solar supply and motor drive.

02

Multiple TS units. One matched drive.

TS6000 units manage solar energy; one drive matches the pump power and current.

03

From configuration to cabinet.

Select configurations such as 11 kW or 22 kW. This draft stays below 50 kW, ending at the source-listed 45 kW rating.

01 / SYSTEM TOPOLOGY

Solar into the cabinet.
Drive to the existing pump.

Based on the multi-TS industrial pump topology, the diagram shows the cabinet boundary, the TS6000 energy managers, the matched drive, and the existing pump. TS6000 quantity and drive rating are selected for the existing pump; the quantity shown is illustrative.

01

Solar DC path

PV groups connect to their TS6000 units. DC outputs combine inside the cabinet and feed one drive.

02

Grid supply path

Three-phase grid power connects to the matched drive’s AC side, working with the solar supply.

03

Existing pump connection

Variable-frequency output connects to the existing motor. Pressure, flow and control interfaces follow site requirements.

02 / CABINET CONFIGURATION

Configure a cabinet
around the existing pump.

Select power to view TS6000 count, the matched drive model and its data. The cabinet illustration communicates the integrated product; enclosure dimensions and layout require final engineering design.

Select complete model:▾
5.5 kW

5.5 kW solar retrofit cabinet

TS6000 × 1 + 5.5 kW drive × 1
Combined TS nominal power 6 kW · P-duty drive reference
Energy managers TS6000 × 1
Drive reference power 5.5 kW (P duty)
Complete drive model VD680E-4T-3.7GB/5.5PB
AC supply reference 3-phase 380V · 50/60Hz
Drive output current 13 A
Drive input current 16.8 A
Drive housing and finished cabinet
Drive W × H × D 100 × 241 × 163 mm
Drive protection IP20
Cabinet dimensions / protection Project-specific
Reference duty P duty · 120% rated current for 60 s
Current and dimensions describe the drive itself. Verify special pump loads against the motor nameplate and duty.
TS count is rounded up from target power ÷ 6 kW for configuration illustration only. Final count depends on electrical input, solar coverage, losses, derating and supported parallel operation; this arithmetic table is not validation of an assembled cabine
Solar energy modules
TS6000 modules combined as required. 6 kW per module is the display basis.
Pump load drive
One matched drive. Confirm G/P duty using motor current and load characteristics.
Control interface reference
Drive documentation includes PID and RS-485. Cabinet interfaces are project-specific.
Enclosure and cooling
Enclosure dimensions, protection and cooling depend on the integrated configuration.
▼ View all 9 reference configurations · 5.5–45 kW
This draft uses VD680E manual P-duty data. The scope is capped at 50 kW. The source lists 45 kW followed by 55 kW, so this page ends at 45 kW.
Pump / P-duty kW TS count¹ TS total kW¹ Matched drive × 1 Output A Input A
5.5 1 6 VD680E-4T-3.7GB/5.5PB 13 16.8
7.5 2 12 VD680E-4T-5.5GB/7.5PB 17 22
11 2 12 VD680E-4T-7.5GB/11PB 25 32.5
15 3 18 VD680E-4T-11GB/15PB 32 41.5
18.5 4 24 VD680E-4T-15GB/18.5PB 37 49.6
22 4 24 VD680E-4T-18.5GB/22PB 45 59
30 5 30 VD680E-4T-22GB/30PB 60 65
37 7 42 VD680E-4T-30G/37P 75 80
45 8 48 VD680E-4T-37G/45P 91 95
¹ Count is rounded up at 6 kW per TS unit and requires engineering verification. Swipe horizontally on mobile.